[vc_row full_width=”stretch_row” parallax=”content-moving-fade” parallax_image=”530″ wrap_container=”yes” no_padding=”yes” css=”.vc_custom_1674228324741{padding-top: 220px !important;padding-bottom: 40px !important;background-position: center;background-repeat: no-repeat;background-size:cover;}”][vc_column][vc_custom_heading text=”HPP OCO 2010 Cascade 168 MW – Peru” use_theme_fonts=”yes” el_class=”title-banner”][/vc_column][/vc_row][vc_row wrap_container=”yes” el_class=”row-project” css=”.vc_custom_1697216804087{padding-top: 60px !important;padding-bottom: 50px !important;}”][vc_column width=”5/12″][vc_single_image image=”542″ img_size=”full”][/vc_column][vc_column width=”7/12″][vc_custom_heading text=”Client” font_container=”tag:h3|text_align:left” use_theme_fonts=”yes”][vc_column_text]OHYSA – Ocoña Hydro S.A.[/vc_column_text][vc_custom_heading text=”Location” font_container=”tag:h3|text_align:left” use_theme_fonts=”yes”][vc_column_text]Arequipa, Peru[/vc_column_text][vc_custom_heading text=”Time Frame” font_container=”tag:h3|text_align:left” use_theme_fonts=”yes”][vc_column_text]2012 – 2013[/vc_column_text][/vc_column][/vc_row][vc_row wrap_container=”yes”][vc_column width=”1/2″][vc_raw_html el_class=”title-section”]JTNDaDMlM0UlM0NzcGFuJTNFU2VydmljZXMlM0MlMkZzcGFuJTNFJTNDJTJGaDMlM0U=[/vc_raw_html][vc_single_image image=”396″][vc_column_text]Feasibility Study and Tender Documents:
- Design Criteria.
- Hydrology and Sedimentation Studies.
- Geology, Geotechnical and Topography Studies.
- Electric Market Studies.
- Optimization Study of the Hydroelectric Power Scheme applying the probabilistic Monte Carlo method.
- Definitive Design of the Hydroelectric Powerplant.
- Concept optimization applying the Monte Carlo method.
- Mainstructures arrangements accordingto topographical and geological studies.
- Energy calculation.
- Cost estimates.
- Design of the main structures at basic design level.
- Financial Evaluation Studies based on the Monte Carlo method.
- Seismic Risk Assessment Studies.
EPO Electrical Grid Connection Study and Permitting
[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_raw_html el_class=”title-section”]JTNDaDMlM0UlM0NzcGFuJTNFVGVjaG5pY2FsJTIwRGV0YWlscyUzQyUyRnNwYW4lM0UlM0MlMkZoMyUzRQ==[/vc_raw_html][vc_single_image image=”396″][vc_column_text]
- Installed capacity: 168 MW
- Plant type: Pure run-of-river type plant
- Head: 230 m
- Turbine type: Francis
- Subterranean work – tunnel length: 19 km
- Powerhouse: Open air
[/vc_column_text][/vc_column][/vc_row]